Buried downspout lines in winter

Underground downspout lines keep yards tidy, but in a Wisconsin winter they can freeze and back up. How to make them work.

Call (920) 764-5805

Last reviewed November 29, 2026.

Downspout elbow
Illustration: a downspout

How a buried line works

A downspout drops into a fitting at grade, and a pipe carries the water underground to an outlet: a pop-up emitter in the lawn, a daylight outlet on a slope, or an approved storm connection. It keeps extensions off the lawn and out of the way of mowers and snow blowers.

Winter problems

Problem Cause Fix
Line frozen solid Water sat in a low spot Re-lay with steady slope
Emitter frozen shut Snow and ice over the cap Clear the emitter; use a daylight outlet
Backup at the downspout Ice downstream Temporary surface extension
Split fittings Freeze expansion Replace fittings

Making buried lines work here

  1. Use smooth-wall pipe, not thin corrugated.
  2. Keep a steady slope to the outlet, with no dips.
  3. Add a clean-out near the downspout.
  4. Daylight the outlet on a slope where possible.
  5. Keep the outlet clear of snow piles.
  6. Have a winter plan: a removable surface extension if the line freezes.

On red clay

Water released at a pop-up emitter in clay soaks in slowly. Place the outlet well away from the house and from neighbors. The county's 1929 soil survey describes a stiff red clay subsoil across much of Brown County.

Never into the sanitary sewer

De Pere is working to remove clear water from its sanitary sewer through its foundation drain disconnection program. Downspout lines must not connect to it.

Testing a buried line

  1. Run a hose into the downspout fitting at full flow.
  2. Watch the outlet. Water should arrive quickly and steadily.
  3. If it backs up, the line is clogged, crushed or has a low spot.
  4. If water appears slowly, there may be a sag holding water.
  5. Use the clean-out to flush or snake the line.

Above-ground winter extensions

A simple fix for lines that freeze: in late fall, fit a removable extension at the top of the buried line so the downspout discharges on the surface for winter, and reconnect in spring.

Common questions

Why do buried downspout lines freeze?

Water left sitting in a low spot or at a pop-up emitter freezes; the next melt backs up.

How deep should they be?

Deep enough and sloped enough to drain completely; low spots are the main problem.

What is a pop-up emitter?

A cap at the end of a line that opens when water flows.

Should I disconnect buried lines in winter?

Some owners switch to above-ground extensions for winter if lines freeze.

Can buried lines go to the sanitary sewer?

No.

Are corrugated pipes OK?

Smooth-wall pipe drains and resists crushing better.

How do I find a buried line's outlet?

Run water and look for where it emerges; a contractor can camera-inspect.